Maxwell Client Update History

From ColorWiki

(Difference between revisions)
Jump to: navigation, search
m (Automatic Instrument Registration & MeasureWatch Verify support)
m (Automatic Instrument Registration & MeasureWatch Verify support)
Line 53: Line 53:
===Automatic Instrument Registration & MeasureWatch Verify support===
===Automatic Instrument Registration & MeasureWatch Verify support===
-
* Plug an instrument into Maxwell Client and an instrument record will be automatically created in Maxwell ("registered"). Also, all measurements with the instrument will be tied to it in Maxwell. So if you're wondering if a failed print might be caused by the instrument you can link right to the instrument and the list all the measurements it's taken to see if the instrument might be at fault....
+
* Plug an instrument into Maxwell Client and an instrument record will be automatically created in Maxwell ("registered"). Also, all measurements with the instrument will be tied to it in Maxwell. So if you're wondering if a failed print might be caused by the instrument you can link directly to the instrument, and the list of all the measurements it has taken, to see if the instrument might be at fault.
* If you have the MeasureWatch Verify service for an instrument, Maxwell Client will automatically configure itself for verification measurements. The instrument will also appear with the MeasureWatch Verify target symbol [[File:MWV.jpg]] in the left menu. MeasureWatch Verify measurements are performed right in the instrument pane. Click on the instrument in the left menu and click “MeasureWatch Verify."
* If you have the MeasureWatch Verify service for an instrument, Maxwell Client will automatically configure itself for verification measurements. The instrument will also appear with the MeasureWatch Verify target symbol [[File:MWV.jpg]] in the left menu. MeasureWatch Verify measurements are performed right in the instrument pane. Click on the instrument in the left menu and click “MeasureWatch Verify."

Revision as of 00:39, 29 June 2016

Here is an overview of the more recent revisions to the Maxwell Client:

Maxwell Client versions:

Contents

Maxwell Client v5.5

March, 2016:

The duplicating function in Maxwell online

Changes in Maxwell online: (not relating to the Client):


v5.5 of Maxwell Client (MXC)

Barbieri Spectro LFP support is here!

http://www.barbierielectronic.com/en/service/downloads-driverfirmware/100-412.html

MemoryScan (LFP, iO, and FP-9)

MemoryScan

For instruments requiring positioning (i1IO, LFP, FD-9) MemoryScan is available to make repetitive jobs easier.

With MemoryScan, a target's position on the scanning table can be memorized for rapid reuse. A separate memory is available for each target definition. Position a target on the scanning table in the same position as before - heavy tape or markers are helpful to ensure target position is repeatable - then 1-click measuring saves tons of time. For example, an i1 IO with MemoryScan makes a compelling proof verification tool.

For busy groups, this could literally save hours per week in proof verification scans. That pays for an iO almost immediately.

Procedure

Select corners in MemoryScan
Setting Memory
Memory Scanning
http://colorwiki.com/wiki/CHROMiX_Measuring#MemoryScan_Positioning


Automatic Instrument Registration & MeasureWatch Verify support

http://colorwiki.com/wiki/Maxwell_Instrument_Handling

Multi-Page Targets & Large-Format HeatMap support

Example of a 3-page target

The Client now supports multi-page targets.

Need to see if your extra-wide digital press (think Indigo 10000) is consistent across the sheet? Until they make an instrument as wide, we need multi-sheet targets that stitch together after measurement to form one contiguous HeatMap. MXC 5.5 can handle it. Work with us to create targets for such a job.

Scanning with multi-page targets
Page completion markers
As each page is completed, a Scan Complete marker will appear on the page and the Measure window will select the next un-scanned page.


AutoScan and Barcodes in Maxwell Client
Barcodes for AutoScan when used with the iSis scanner can now include page numbers. The MD03 barcode format can only be used with Maxwell Client v5.5 or later.


When scanning multi-page AutoScan targets, pages can be scanned in any order and selecting the correct page will happen automatically.


http://colorwiki.com/wiki/CHROMiX_Measuring#Multi-page_Targets



i1Profiler and Barbieri Gateway target format support

Pass/Fail evaluation for Hot Folders

OTHER

There are lots of other small changes and improvements under the skin.


Maxwell Client v5.0.4


Maxwell Client v5.0.3

Maxwell Client v5.0.2

Maxwell Client v5.0.1

Maxwell Client v5.0

Personal tools
Namespaces
Variants
Actions
Navigation
Toolbox