Maxwell Color Set Details
From ColorWiki
Maxwell Table of Contents
Getting Started - Where to Find Help
- Sign up for an Account
- Create a new Device and a Track
- Adding a Custom Reference
- Upload Measurements into your Track
- Maxwell Client - Automatic measurement uploads
- Viewing your Measurements
- Viewing a Trend Report
- Multi-Dimensional Reporting
- Using Notifiers in Maxwell
- Some helpful suggestions for using Maxwell
- About Maxwell
- Glossary
- Contact Us
Once you have measurements of your devices uploaded into Maxwell, there is a great wealth of information that you can obtain. You have several different options for viewing your colors.
To access the Color Set Details click on a track, choose Measurements, choose an individual measurement, and see the list under "Related Items." This page explains in detail what you can do with a measurement or other color set.
Contents |
Colors
- All the colors in the colorlist are presented in the order that they are represented on the colorlist file.
- Any of the colors can be clicked on to present a histogram of the color, XYZ values, etc.
Channel Report
The Channel Report uses SmartTargetTM technology to:
- Find single-ink patches
- Automatically calculate dot gains (using the calculation engine in CHROMiX's ColorThink Pro software.)
Note: Channel Report requires CMYK data. (It will not work with RGB data.)
Solid Colors
The Solid Colors report uses SmartTargetTM technology to pull key patches from the target, including:
- "Paper" white
- 100% Cyan, 100%, Magenta, 100% Yellow, 100% black
- 300% ink patches, 400% ink patches
This feature provides a quick and easy way to view these important colors without having to remember where they are on the target.
For example, you can check to see if your paper has any optical brighteners by quickly choosing the paper white patch and viewing the histogram.
For more information on optical brightners, click here.
Note: These patches must exist in the color set in order for Maxwell to find them! Solid Colors requires CMYK data.
Target View
Target View will display the target colors in the correct dimensions if Maxwell can recognize the target contents.
In addition, you can:
- Mouse over any color on the target and view the address of the color
- View a color-accurate enlarged sample swatch of the color
- See the total number of patches in the target
Clicking again on any color in the target will
- Open up the color detail
- Show a histogram of the color
- Show XYZ information
ab Plot
The a/b Plot is a representation of the colorset as it would be seen in Lab colorspace. This is a 2-dimensional view of your colors showing hue and saturation (but not luminance.)
- All the colors shown in Maxwell are taken from the actual color data itself, converted to sRGB in order to be viewed correctly on internet browsers.
Results Summary
The Results Summary pane is a very powerful tool which can be used to diagnose problems and identify what colors are falling outside of the metric tolerance.
Metric Summary
The Metric Summary duplicates the metric results as they would be seen by the ColorShuttle Label.
dE Histogram
The delta E histogram will confirm which delta E calculation is being used here: dE2000 or dE76.
The histogram identifies which delta E result occurs most often in the data, providing you with a typical "bell curve" - popular for identifying trends in data.
Patch to Patch Comparison
The Patch to Patch Comparison provides a direct comparison between the reference patches and the corresponding sample patches. This includes:
- Lab values for each sample patch
- Actual representative colors for each patch
- The name for each color (as defined by the reference set that was used.)
- A delta E column showing the precise difference between each reference and sample patch.
Note that each of these columns are able to be sorted. Here are some examples of how to use this powerful feature:
- For example, if you click on the "dE" column header, all of the colors in the list are sorted according to smallest to the largest dE values. Clicking the dE heading again will sort them all from highest to lowest. This is very useful for quickly determining the worst colors and identifying common characteristics.
- Click on the "DeviceValues" header to order the list according to device values. You can quickly identify duplicate patches if your color list contains any.
Add to Report
For information on how to add your Color Set to a Report, go to Maxwell_Reports.